LI-215A 15 Amps for CISPR 16 & ANSI C63.4 9 kHz - 30 MHz

The LI-215A Line Impedance Stabilization Network (LISN) provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products. The LI-215A is compliant with both CISPR 16-1-2 and ANSI C63.4. The LISN provides defined stable impedance and isolates the EUT from power source influences, thereby providing accurate and repeatable results.

The LI-215A includes one pair of single-conductor networks, housed together, to be installed in series with each current-carrying conductor in a single- phase, dual-phase or DC power system. A second LI-215A pair can be used to accommodate 3-phase power systems (Wye or Delta configurations). The LI-215A is equipped with IEC connector at the mains (power input) and NEMA 5-15R at EUT (power output) ports. This LISN uses air-core inductors to prevent saturation and permeability variation.

The mounting plate of the LI-215A is left unpainted in order to facilitate connection to earth ground in its installation, which is essential due to high leakage current. Use of a Transient Limiter for impedance matching, reduction of out-of-band emissions and transient protection for your measurement instrument is highly recommended and available from Com- Power. All Com-Power LISNs are individually calibrated in compliance with the relevant requirements of CISPR 16-1-2 and ANSI C63.4. Impedance, Phase, Isolation, and Insertion Loss data is supplied with each unit, along with the calibration certificate.

Features:

Frequency range of 9 kHz to 30 MHz
Fully compliant with CISPR 16-1-2 / ANSI C63.4
“Air-core” inductors to prevent saturation
Individual Calibration Included
Three-Year Warranty

Specifications:

Product Name: Line Impedance Stabilization Network (LISN)
Specification: CISPR 16-1-2 / ANSI C63.4
Application: Power Line conducted emission tests
Frequency Range: 9 KHz – 30 MHz
RF Connector: 50 Ohms N-type (female)
Current Rating: 15 Ampere AC, 10 Ampere DC
Voltage Rating: 270 VAC (Line to Ground), 380 VDC
Inductors: 250 & 50 microhenry (air-core)
Mains & EUT Connections: IEC 60320 @ Mains and NEMA 5-15 R @ EUT
Dimensions (each network): 17 × 16 × 7 inches / 43 × 40 × 18 cm
Weight (each network): 21 lbs / 9.5 kg
Insertion Loss: < 6 dB (150 kHz – 30 MHz)